Home Products About us Feedback Service Contact us E-mail
Ventilator JH-2000B - Ventilator - Taizhou Juhao Import & Export Co., Ltd.
 Products Category
 
>> Clinical Analysis Equipments
>> Surgical Equipments
>> Laboratory Equipment
>> Ward Nursing Equipments
>> Electronic Apparatus
>> Ultrasonic Equipments
>> Radiology Equipments
>> Dental Equipments
>> E.N.T. Equipments
>> Opitcal Apparatus
>> Sterilizer
 
 
Products Search :
   
download
   
Gangcheng Road,Gaogang District,Taizhou City,China
86-523-86982557
86-523-86985557
Maggie
www.jh-medical.com
info@jh-medical.com
 
Current Position: Home >> Product >> Ventilator
 

Ventilator JH-2000B

 

 

Technical Specification

  • Display: Colored LCD, touch screen setting , big font display, free changeable angles of views.
  • Various ventilation modes : SIPPV¡¢SIMV¡¢PCV¡¢SPONT¡¢MANUAL¡¢CPAP
  • Ventilation parameters : PEEP¡¢SIGH¡¢IRV¡¢Inspiratory platform
  • Tidal Volume : 50-1500 mL
  • Rate : 1¡«99bpm
  • SIMV rate : 2¡«20bpm
  • I:E : 4:1¡«1:8
  • Trigger sensitivity : -1.0¡«1.0kPa 
  • PEEP : 0¡«25cmH2O
  • Pressure control : 3¡«50cmH2
  • SIGH : 1.5 times the inspiratory time (60 ~ 120 times adjustable)
  • Inspiratory platform : 0¡«50%
  • Oxygen concentration : 48%¡«100%
  • Pressure limit : 5¡«60cmH2O
  • Parameters for ventilation monitoring : Tidal volume, ventilation volume, IPPV rate, total respiratory rate, peak pressure of airway, pressure - time waveform, flow rate - time waveform, inspiratory trigger pressure, Inspiratory platform, Oxygen concentration, battery capacity, Safety alarm system.
  • Airway pressure alarm : Upper limit setting range 0.3¡«6.0 kPa,

                                               Lower limit setting range 0.2¡«5.0 kPa.

  • Per-minute ventilation volume alarm : Upper limit setting range 3.0¡«30L/min, 

                                                                   Lower limit setting range 1.0¡«10L/min.

  • Vt alarm : Upper limit setting range 10¡«2000ml,

                          Lower limit setting range 0¡«1800 ml.

  • Sustained high-pressure alarm : It will give alarm when stress have consistently been higher than 2.5 kPa.  
  • Suffocation alarm : It will give sound and light alarm if there is no tidal volume input for 15 seconds. 
  • Power : AC 220V¡À10%    50Hz¡À1Hz  UPS, Storage battery

 

 

Power failure alarm
Battery under-voltage alarm  
Power loss alarm     
Intubation off alarm